FANUC Series 0i-F / 0i-F Plus warning DS0307: APC ALARM: BATTERY LOW 1

FANUC Series 0i-F / 0i-F PluswarningChecked against Series 0i-MODEL F documentation (B-64607EN/01)
Technical review pending. This guide is based on the cited manufacturer documentation; check it against the manual for your exact model and firmware before acting.

DS0307 (APC ALARM: BATTERY LOW 1) on a FANUC 0i-F means the absolute position detector battery voltage has dropped to a level at which replacement is required. The position data is still held, and FANUC says to replace the battery with the machine turned on so the absolute position is kept.

Diagnose this with AI

Upload a keypad photo, the fault history or a parameter export from your FANUC Series 0i-F / 0i-F Plus. InduQT compares the evidence and suggests the next useful checks.

Try Free CNC Alarm Diagnostic

When it happens

Likely causes and checks

1Battery at end of life

Points to it
Alarm after a long service period; DGN 3019 shows the detector concerned.
Check
Replace the batteries with the machine (CNC) powered on and an emergency stop applied, within a week of the alarm, by trained personnel; FANUC refers to the alpha i servo motor maintenance manual for the detailed procedure.

2Wrong or poor-quality replacement battery

Points to it
Alarm returns soon after a recent replacement.
Check
Check the battery type and voltage against FANUC’s specification for the amplifier battery case.

3Battery connection resistance

Points to it
Battery measures good out of circuit but alarm persists on one axis.
Check
Inspect the battery holder and cable to that amplifier.

Telling it apart

Relevant parameters

ParameterNameWhy it matters
DGN 3019 (diagnosis)Detector battery exhaustionABP, INP and EXP bits show which detector battery is low.

Evidence to collect