FANUC Series 0i-F / 0i-F Plus alarm SP9012: OVERCURRENT POWER CIRCUIT

FANUC Series 0i-F / 0i-F PlusfaultChecked against Series 0i-MODEL F documentation (B-64607EN/01)
Technical review pending. This guide is based on the cited manufacturer documentation; check it against the manual for your exact model and firmware before acting.

SP9012 (OVERCURRENT POWER CIRCUIT) on a FANUC 0i-F means the spindle motor current was abnormally high; the spindle amplifier shows alarm 12. FANUC lists poor motor insulation, a motor-specific parameter that does not match the motor model, and a faulty spindle amplifier.

Diagnose this with AI

Upload a keypad photo, the fault history or a parameter export from your FANUC Series 0i-F / 0i-F Plus. InduQT compares the evidence and suggests the next useful checks.

Try Free CNC Alarm Diagnostic

When it happens

Likely causes and checks

1Motor or cable insulation breakdown

Points to it
Coolant ingress, damaged cable, or alarm worse when wet; may come with SP9003 (DC-link fuse blown).
Check
Insulation-test the spindle motor and power cable with them disconnected from the amplifier.

2Spindle parameters do not match the motor

Points to it
Started after a motor replacement or parameter reload.
Check
Compare the motor-specific spindle parameters with the motor model and the builder’s backup.

3Spindle amplifier fault

Points to it
Motor and cable test good and parameters match, but the alarm repeats.
Check
Replace the spindle amplifier per FANUC’s remedy, after the motor and parameter checks.

Telling it apart

Evidence to collect

Work on fuel trains, burners, pressure vessels and electrical equipment must be done by qualified personnel following the manufacturer’s documentation and local codes. Never bypass a safety device or interlock.