FANUC αi series servo amplifier (SVM, PSM) troubleshooting

FANUC
Technical review pending. This guide is based on the cited manufacturer documentation; check it against the manual for your exact model and firmware before acting.

FANUC αi servo amplifiers are modular: a power supply module (PSM) feeds a DC link to servo amplifier modules (SVM) and spindle amplifier modules (SPM), all under a FANUC CNC. An alarm shows twice: as a single character on the module’s 7-segment STATUS display and as a servo alarm number on the CNC. Reading both together locates the fault. This record covers the αi series in FANUC maintenance manual B-65285EN/03; the later αi-B and αi-D series have their own manuals and are not covered here.

Diagnose this with AI

Upload a photo of the alarm screen, the fault history or a data export. InduQT compares the evidence and suggests the next useful checks.

Try Free Servo Diagnostic

How it reports faults

Fault codes

CodeName
PSM 1Converter: input circuit overcurrent / IPM abnormal (CNC 437, SV0437)
PSM 2Converter: cooling fan stopped (CNC 443, SV0443)
PSM 3Converter: main circuit overload (CNC 431, SV0431)
PSM 4Converter: DC link undervoltage (CNC 433, SV0433)
PSM 5Converter: DC link precharge failure (CNC 442, SV0442)
PSM 6Converter: control power supply undervoltage (CNC 432, SV0432)
PSM 7Converter: DC link overvoltage (CNC 439, SV0439)
PSM 8Converter: excessive regenerative power (CNC 605, SV0605)
PSM AConverter: radiator cooling fan stopped (CNC 606, SV0606)
PSM EOpen phase in the converter main power supply (CNC 607, SV0607)
PSM HConverter: excessive deceleration power (CNC 440, SV0440)
SVM 1Inverter: internal cooling fan stopped (CNC 444, SV0444)
SVM 2Inverter: control power supply undervoltage (CNC 434, SV0434)
SVM 5Inverter: DC link undervoltage (CNC 435, SV0435)
SVM 6Inverter: overheat (CNC 602, SV0602)
SVM FInverter: radiator cooling fan stopped (CNC 601, SV0601)
SVM PCommunication error between amplifier and module (CNC 604, SV0604)
SVM 8Inverter: DC link current alarm, L axis (CNC 600, SV0600)
SVM 8.Inverter: IPM alarm, L axis (CNC 449 or 603 for IPM overheat)
SVM bInverter: motor current alarm, L axis (CNC 438, SV0438); c = M axis, d = N axis
SVM UInverter: FSSB communication error, COP10B
SVM LInverter: FSSB communication error, COP10A
CNC 436Soft thermal (OVC), no amplifier display (SV0436 on 15i)
CNC 430Servo motor overheat (SV0430 on 15i)
CNC 445Soft disconnection alarm (SV0445 on 15i)

Evidence to collect

Work on fuel trains, burners, pressure vessels and electrical equipment must be done by qualified personnel following the manufacturer’s documentation and local codes. Never bypass a safety device or interlock.