FANUC Series 0i-F / 0i-F Plus alarm SV0401: IMPROPER V_READY OFF

FANUC Series 0i-F / 0i-F PlusfaultChecked against Series 0i-MODEL F documentation (B-64607EN/01)
Technical review pending. This guide is based on the cited manufacturer documentation; check it against the manual for your exact model and firmware before acting.

SV0401 (IMPROPER V_READY OFF) on a FANUC 0i-F means the velocity-control ready signal (VRDY) from the servo amplifier was OFF although the position-control ready signal (PRDY) was ON. In practice the amplifier stopped being ready to drive the motors, so SV0401 is usually a consequence: the root cause is whatever made the amplifier drop out.

Diagnose this with AI

Upload a keypad photo, the fault history or a parameter export from your FANUC Series 0i-F / 0i-F Plus. InduQT compares the evidence and suggests the next useful checks.

Try Free CNC Alarm Diagnostic

When it happens

Likely causes and checks

1Another amplifier or power-supply alarm dropped the MCC

Points to it
Other SV or SP alarms appear in the same alarm screen or alarm history at the same time; several axes show SV0401 together.
Check
Read the full alarm list and the amplifier displays, and clear the first alarm first. FANUC notes that on a multi-axis amplifier shared between paths, an alarm on one path’s axis drops the MCC and raises SV0401 (with SV0007) on the other path.

2Emergency stop chain or converter not ready

Points to it
Alarm appears when releasing E-stop or at power-up; DGN 358 bit *ESP or CRDY is 0.
Check
Read DGN 358 as binary and find the first 0 between bits 5 and 14: *ESP (converter E-stop released), CRDY (converter ready), INTL (DB relay released), DRDY and SRDY (amplifier ready). The first missing bit is the step that failed.

3Dynamic-brake relay or amplifier hardware not reaching ready

Points to it
DGN 358 shows *ESP and CRDY set but INTL or DRDY missing; repeats on the same amplifier.
Check
Note the amplifier LED and the DGN 358 value and compare with the FANUC alpha i servo amplifier maintenance manual before replacing the amplifier.

4Low supply to the power supply module

Points to it
Alarm coincides with plant supply dips or other machines starting; may come with SV0433 or SV0435 (low DC link).
Check
Have a qualified electrician measure the three-phase input to the power supply module under load and compare with its rating.

Telling it apart

Relevant parameters

ParameterNameWhy it matters
DGN 358 (diagnosis)V ready-off informationBits 5–14 are set in sequence during amplifier start-up; the first bit still 0 shows where the sequence stopped.

Evidence to collect

Work on fuel trains, burners, pressure vessels and electrical equipment must be done by qualified personnel following the manufacturer’s documentation and local codes. Never bypass a safety device or interlock.