Allen-Bradley Kinetix 5700 servo drive troubleshooting

Allen-Bradley14.001 or later
Technical review pending. This guide is based on the cited manufacturer documentation; check it against the manual for your exact model and firmware before acting.

The Kinetix 5700 is Rockwell Automation’s multi-axis servo drive system on EtherNet/IP, with DC-bus power supplies, regenerative bus supplies and single- and dual-axis inverters controlled from a Logix 5000 controller. Faults are shown on each module’s LCD as text such as “FLT S54 – POSN ERROR” and are also reported to the controller axis tags.

Diagnose this with AI

Upload a photo of the alarm screen, the fault history or a data export. InduQT compares the evidence and suggests the next useful checks.

Try Free Servo Diagnostic

How it reports faults

Fault codes

CodeName
FLT S54POSN ERROR (Excessive Position Error Fault)
FLT S43FDBK LOSS FL (Feedback Signal Loss, factory limit)
FLT S07MTR OVERLOAD FL (Motor Thermal Overload, factory limit)
FLT S03MTR OVERSPEED FL – Motor overspeed, factory limit
FLT S05MTR OVERTEMP FL – Motor overtemperature, factory limit
FLT S08MTR OVERLOAD UL – Motor thermal overload, user limit
FLT S10INV OVERCURRENT – Inverter overcurrent
FLT S13INV OVERLOAD FL – Inverter thermal overload, factory limit
FLT S16GROUND CURRENT FL – Ground current, factory limit
FLT S22AC POWER LOSS
FLT S23AC PHASE LOSS
FLT S33BUS UNDERVOLT FL – DC-bus undervoltage, factory limit
FLT S35BUS OVERVOLT FL – DC-bus overvoltage, factory limit
FLT S37BUS POWER LOSS
FLT S45FDBK COMM FL – Motor feedback data loss, factory limit
FLT S47FDBK DEVICE FAILURE – Motor feedback device failure
FLT S50POS HW OTRAVEL – Positive hardware overtravel
FLT S51NEG HW OTRAVEL – Negative hardware overtravel
FLT S55VEL ERROR – Excessive velocity error
FLT S56OVERTORQUE LIMIT
FLT S61ENABLE INPUT
FLT M05FDBK BATTERY LOSS – Battery low, absolute position lost
FLT M06FDBK BATTERY LOW
INIT FLT M03MTR ENC STARTUP – Motor feedback communication startup
NODE FLT 01LATE CTRL UPDATE – Control connection update fault
INHIBIT M05SAFE TORQUE OFF – Start inhibit, safe torque off

Evidence to collect

Work on fuel trains, burners, pressure vessels and electrical equipment must be done by qualified personnel following the manufacturer’s documentation and local codes. Never bypass a safety device or interlock.