Allen-Bradley Kinetix 5700 servo drive alarm FLT S07: MTR OVERLOAD FL (Motor Thermal Overload, factory limit)

Allen-Bradley Kinetix 5700 servo drivefault14.001 or later
Technical review pending. This guide is based on the cited manufacturer documentation; check it against the manual for your exact model and firmware before acting.

Fault FLT S07 – MTR OVERLOAD FL on an Allen-Bradley Kinetix 5700 is Motor Thermal Overload (factory limit): the motor thermal model exceeded its factory-set thermal capacity limit.

Diagnose this with AI

Upload a keypad photo, the fault history or a parameter export from your Allen-Bradley Kinetix 5700 servo drive. InduQT compares the evidence and suggests the next useful checks.

Try Free Servo Diagnostic

When it happens

Likely causes and checks

1Motion profile too demanding for the motor

Points to it
Fault appears after a cycle-time reduction or speed increase.
Check
Modify the command profile to reduce speed or increase time, as Rockwell directs; compare RMS torque with the motor continuous rating.

2Mechanical load increased (friction, binding, brake drag)

Points to it
Torque at constant speed has risen over time.
Check
Trend torque at constant speed and inspect lubrication, alignment and brake release.

3Holding torque at standstill

Points to it
Vertical axis or counterbalance problem; fault without much motion.
Check
Check holding torque and the counterbalance.

Telling it apart

Relevant parameters

ParameterNameWhy it matters
Motor Thermal Overload User LimitAxis attributeSets the user limit for FLT S08; S07 uses the factory limit.

Evidence to collect

Work on fuel trains, burners, pressure vessels and electrical equipment must be done by qualified personnel following the manufacturer’s documentation and local codes. Never bypass a safety device or interlock.