FANUC Series 0i-F / 0i-F Plus alarm OT0500: + OVERTRAVEL (SOFT 1)

FANUC Series 0i-F / 0i-F PlusfaultChecked against Series 0i-MODEL F documentation (B-64607EN/01)
Technical review pending. This guide is based on the cited manufacturer documentation; check it against the manual for your exact model and firmware before acting.

OT0500 (+ OVERTRAVEL (SOFT 1)) on a FANUC 0i-F means an axis exceeded the positive-side stored stroke check 1, the software travel limit set in parameter 1320; OT0501 is the same on the negative side (parameter 1321). The limit is in machine coordinates, so it is only as accurate as the axis’s reference position.

Diagnose this with AI

Upload a keypad photo, the fault history or a parameter export from your FANUC Series 0i-F / 0i-F Plus. InduQT compares the evidence and suggests the next useful checks.

Try Free CNC Alarm Diagnostic

When it happens

Likely causes and checks

1Program, work offset or tool offset sends the axis beyond travel

Points to it
Happens in automatic operation at a particular block; machine reference is otherwise correct.
Check
Check the block’s end point in machine coordinates, the active work offset and the tool length or wear offsets.

2Operator jogged past the limit

Points to it
Manual mode; alarm only stops the jogged axis.
Check
Jog the axis back in the opposite direction, then press RESET (unless parameter 1301#4 OF1 is set, which clears the alarm as soon as the axis is back in range).

3Reference position wrong or lost

Points to it
Limits seem to have moved; machine position looks wrong after power-up, a battery alarm, a crash or motor work.
Check
Check the alarm history for DS0300/DS0306 and re-establish the reference position per the builder’s procedure before trusting the limits.

4Stroke limit parameters changed

Points to it
Started after a parameter load or edit.
Check
Compare parameters 1320 and 1321 with the builder’s backup.

Telling it apart

Relevant parameters

ParameterNameWhy it matters
1320Stored stroke check 1, positive directionPositive software travel limit in machine coordinates (OT0500).
1321Stored stroke check 1, negative directionNegative software travel limit in machine coordinates (OT0501).
1301#4 (OF1)Cancel OT alarm when back in range0: alarm stays until RESET after moving back into range; 1: alarm cancels immediately.
1300#6 (LZR)Stroke check before reference returnWith 1311#0 DOT = 1, sets whether the check runs before the first manual reference return after power-on.

Evidence to collect

Work on fuel trains, burners, pressure vessels and electrical equipment must be done by qualified personnel following the manufacturer’s documentation and local codes. Never bypass a safety device or interlock.