Allen-Bradley (Rockwell Automation) PowerFlex 525 troubleshooting

Allen-Bradley (Rockwell Automation)
Technical review pending. This guide is based on the cited manufacturer documentation; check it against the manual for your exact model and firmware before acting.

The PowerFlex 525 is Rockwell Automation’s compact AC drive in the PowerFlex 520-series (Bulletin 25B). Faults are shown as a flashing F-number on the integral LCD. Each fault is Type 1 (can be auto-reset and restarted by A541 [Auto Rstrt Tries]) or Type 2 (non-resettable by auto restart; the cause must be corrected first).

Diagnose this with AI

Upload a photo of the alarm screen, the fault history or a data export. InduQT compares the evidence and suggests the next useful checks.

Try Free Drive Diagnostic

How it reports faults

Fault codes

CodeName
F004UnderVoltage
F005OverVoltage
F007Motor Overload
F012HW OverCurrent
F013Ground Fault
F033Auto Rstrt Tries
F081DSI Comm Loss
F002Auxiliary Input
F003Power Loss
F006Motor Stalled
F008Heatsink OvrTmp
F009CC OvrTmp
F015Load Loss
F021Output Ph Loss
F029Analog In Loss
F038Phase U to Gnd
F039Phase V to Gnd
F040Phase W to Gnd
F041Phase UV Short
F042Phase UW Short
F043Phase VW Short
F048Params Defaulted
F059Safety Open
F063SW OverCurrent
F064Drive Overload
F070Power Unit
F071DSI Net Loss
F072Opt Net Loss
F073EN Net Loss
F080Autotune Failure
F082Opt Comm Loss
F083EN Comm Loss
F091Encoder Loss
F100Parameter Chksum
F111Safety Hardware
F114uC Failure
F122I/O Board Fail

Evidence to collect

Work on fuel trains, burners, pressure vessels and electrical equipment must be done by qualified personnel following the manufacturer’s documentation and local codes. Never bypass a safety device or interlock.