Readings kept in Google Sheets, or a CSV that a system refreshes on Google Drive, OneDrive or SharePoint, can be imported once or polled on a schedule. The sheet uses the same layout as a CSV import.
Publish the sheet as CSV
- Open Publish to web
In Google Sheets choose File → Share → Publish to web.
- Pick the tab and format
Select the tab with the readings (not the whole document) and Comma-separated values (.csv), then Publish.
- Copy the link
It ends in
output=csv. Anyone with the link can read that tab, so publish only the data you mean to share.
For a file on Google Drive, use a direct download link: https://drive.google.com/uc?export=download&id=FILE_ID, with the file shared as “Anyone with the link”. For OneDrive or SharePoint, use a download link (ending in download=1).
Poll it on a schedule
Create an http_pull connector. In the app: open the site, choose Google Sheets or Drive link, then Create scheduled import. Or with the API:
curl -X POST "https://api.induqt.ai/v1/connectors" \
-H "Authorization: Bearer $INDUQT_API_KEY" \
-H "Content-Type: application/json" \
-d '{
"siteId": "6f1c2c0e-4b1a-4c55-9d0e-1f2a3b4c5d6e",
"type": "http_pull",
"name": "B-101 log sheet",
"config": {
"url": "https://docs.google.com/spreadsheets/d/e/…/pub?output=csv",
"intervalSeconds": 300
},
"mapping": {
"machine": "B-101",
"timeColumn": "Timestamp"
}
}'| Name | Description |
|---|---|
urlrequired | https link returning CSV, XLSX or JSON: Google Sheets File → Share → Publish to web → CSV, a Drive/OneDrive direct download link, or your own endpoint. |
intervalSeconds | How often to fetch, 60–86,400. Default 300. |
headers | Extra request headers, e.g. an Authorization header. Encrypted at rest. |
Mapping. machine (id or externalId) for the whole file, or machineColumn when rows name their machine; timeColumn (default: detected). Rows already loaded are skipped.
Import once
To load a sheet a single time, pass its link as url to the import endpoint:
curl -X POST "https://api.induqt.ai/v1/machines/0b7d9a12-7c3e-4f10-a2b4-c5d6e7f8a9b0/imports" \
-H "Authorization: Bearer $INDUQT_API_KEY" \
-H "Content-Type: application/json" \
-d '{
"url": "https://docs.google.com/spreadsheets/d/e/…/pub?gid=0&single=true&output=csv",
"timeColumn": "Timestamp"
}'Troubleshooting
| Symptom | Likely cause and fix |
|---|---|
| Got HTML, not CSV | The link is the normal sharing link. Use the Publish to web link ending in output=csv, or a Drive uc?export=download link. |
| 403 or sign-in page | The sheet or file is private. Publish it, or share the file with anyone who has the link. |
| New rows appear late | Google refreshes published CSVs every few minutes, so very recent edits can lag. Polling faster than about five minutes does not help. |
| Rows from several machines | Add a column naming the machine and set machineColumn in the mapping. |