FANUC 0i-F DS0307 APC ALARM: BATTERY LOW 1, what to check first?

Question

I'm getting a DS0307 APC ALARM: BATTERY LOW 1 on my FANUC 0i-F controller. It popped up at power-up this morning. What's the most likely cause and what should I check first?

Top answer · Written by InduQT from the fault guide and manufacturer manuals cited below · Oct 28, 2026

The DS0307 alarm on a FANUC 0i-F controller indicates that the absolute position detector battery voltage is low and requires replacement. The position data is still held, but the battery should be replaced soon to prevent data loss. This alarm is distinct from DS0306, which means data has already been lost, or DS0308, which is a historical low voltage record.

Likely causes and checks

1Battery at end of life

Points to it
Batteries have a finite lifespan and will eventually need replacement. This is the most common reason for this alarm, especially if the batteries haven't been changed in a long time.
Check
Replace the batteries with the machine (CNC) powered on and an emergency stop applied. This should be done by trained personnel within a week of the alarm. Refer to the alpha i servo motor maintenance manual for the detailed procedure.

2Wrong or poor-quality replacement battery

Points to it
If the alarm returns shortly after a recent battery replacement, it suggests the new battery might not be the correct type or quality, leading to premature voltage drop.
Check
Verify the battery type and voltage against FANUC's specifications for the amplifier battery case.

3Battery connection resistance

Points to it
Even if the battery itself is good, a poor connection can prevent proper voltage delivery to the absolute position detector, triggering the alarm.
Check
Inspect the battery holder and the cable leading to the affected amplifier for any signs of corrosion or loose connections.

Next check: Given that the alarm appeared at power-up and no recent battery replacement was mentioned, the most probable cause is that the battery has reached its end of life. The immediate next step should be to prepare for battery replacement, ensuring the machine remains powered on during the procedure to retain absolute position data.

Work on fuel trains, burners, pressure vessels and electrical equipment must be done by qualified personnel following the manufacturer’s documentation and local codes. Never bypass a safety device or interlock.